Comparison ledger
Keysight 3070 Series 3 ICT, Teradyne TS 121 ICT, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 3070 Series 3 ICTKeysight | TS 121 ICTTeradyne |
|---|---|---|
| OEM | Keysight | Teradyne |
| Category | Test & Probe | Test & Probe |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | Keysight 3070 | Teradyne TS 121 ICT |
| Cited variants | — | |
| Specifications | ||
| Required Pressure | 6-7 bar[1] | — |
| Average Air Consumption | 100-170 l/min[1] | — |
| 2 Programmable DC Power Supplies | HP 6624 A[1] | — |
| Configuration | HP Visualise B 180 L Workstation[1] | Windows XP[5] |
| Bank 1 | Modules 0,1[1] | — |
| Bank 2 | Modules 2,3[1] | — |
| Programmable DC Power Supplies | 2 × HP 6624A[1] | — |
| Workstation | HP Visualise B 180 L[1] | — |
| Measurement Card Banks | 2 banks, each with 2 modules (Bank 1: Modules 0,1; Bank 2: Modules 2,3)[1] | — |
| Card Numbers per Bank | 23 card numbers[1] | — |
| Coins per Row on Cards | 78 coins per row, cards have 1 or 2 rows[1] | — |
| Computer Operating System | Unix[1] | — |
| Measurement Card Structure | 2 banks each with 2 modules; Bank 1: Modules 0,1; Bank 2: Modules 2,3; Each bank contains 23 card numbers; Cards can have 1 or 2 rows with 78 coins per row[1] | — |
| PIN Cards (Asset 155552) | 8[1] | — |
| PIN Cards (Asset 155549) | 18[4] | — |
| ASRU Rev. C Cards | 2[1] | — |
| Control Cards | 2 x xT64 Control Cards[1] | — |
| External Power Supplies | 2[1] | — |
| MPU (Asset 155552) | 1[1] | — |
| MPU (Assets 155551,155550,155549) | 2[2] | — |
| Access Card | 1[1] | — |
| Computer | Unix Computer[1] | — |
| Vintage (Asset 155552) | 2005[1] | — |
| Vintage (Asset 155551) | 2004[2] | — |
| Vintage (Asset 155550) | 2008[3] | — |
| Vintage (Asset 155549) | 2004[4] | — |
| Asset type | In Circuit Tester[1] | — |
| Measurement cards | 2 banks, each with 2 modules; Bank 1: Modules 0,1; Bank 2: Modules 2,3[1] | — |
| Cards per bank | 23 card numbers[1] | — |
| Card row capacity | 1 or 2 rows with 78 coins per row[1] | — |
| Equipped with | 8 PIN Cards[1] | — |
| Control computer | Unix Computer[1] | — |
| Measurement Banks | 2 banks, each with 2 modules[1] | — |
| Card Configuration | 1 or 2 rows with 78 coins per row[1] | — |
| PIN Cards | 8 (or 18 on one variant)[1] | — |
| ASRU Cards | 2 Rev. C[1] | — |
| Current S/W Version | — | Teradyne Navigate 6.4.0.0.28[5] |
| Pinboard Type | — | Ultra 121[5] |
| Pinboard Capacity | — | 30 (currently GDMS has 16 boards)[5] |
| Max Real Nails | — | 3840 (currently GDMS has 2080 nails)[5] |
| Mux Ratio | — | 1:1[5] |
| DC voltage source | — | ±18V[5] |
| DC current source | — | ±500mA[5] |
| DC voltmeter | — | 0 to ±200V[5] |
| DC ammeter | — | 0 to ±160mA[5] |
| Resistance Range | — | 0.1 to 30MΩ[5] |
| Equipment type | — | In-circuit tester[6] |
| Operating system | — | Windows XP[5] |
| Software | — | Teradyne Navigate 6.4.0.0.28[5] |
| Pinboard capacity | — | 30[5] |
| Max real nails | — | 3840[5] |
| Fixed power supply | — | +5V, 6A[5] |
| Variable power supply | — | +20V, 8A (2)[5] |
| Automatic vacuum control | — | For clamshell fixtures[5] |
| Capacitive range | — | 1pF to 10,000F[5] |
| Inductive range | — | 10H to 1000H[5] |
| Programmable frequency range | — | 15Hz to 100kHz[5] |
| Programmable AC level | — | 0 to 7Vrms[5] |
| Programmable DC offset | — | Present[5] |
| Programmable drive levels | — | 26 levels, +5.5V to -2.5V[5] |
| Programmable sense thresholds | — | 26 thresholds, +5.5V to -2.5V[5] |
| Calibration | — | Traceable calibration daughterboard[5] |
| 26 Programmable Drive Levels, Range | — | +5.5V to –2.5V[5] |
| 26 Programmable Sense Thresholds, Range | — | +5.5V to –2.5V[5] |
| Manufacturer | — | Teradyne[5] |
| Model | — | TS 121 ICT[5] |
| Category | — | Test & Probe[6] |