Applied Materials 0010-03254 E Chuck, Thermo Fisher Scientific FEI Helios NanoLab 600 FIB, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
0010-03254 E ChuckApplied Materials
OEMApplied MaterialsThermo Fisher
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
Family—Thermo Fisher Scientific FEI Helios NanoLab 600 FIB
Specifications
Configuration—Dual beam[1]
Sample stage—5-Axes motorized X-Y-Z-rotate-tilt stage[1]
Step size—100 nm (Minimum)[1]
High vacuum—10^-10 mbar[1]
X, Y-Axis—150 mm[1]
Z-Axis—10 mm[1]
Tilt range—-5° to +60°[1]
Source—SCHOTTKY Field emitter[1]
Accelerating voltage—350 V to 30 kV (Continuously adjustable)[1]
Beam current—1 pA - 22 nA[1]
Type—Dual beam[1]
Vacuum system—Edwards XDS10 Scroll pump[1]
Travel X, Y-Axis—150 mm[1]
Travel Z-Axis—10 mm[1]
Repeatability—1 µm at 0°; 2 µ at 52°[1]
Electron source—SCHOTTKY Field emitter[1]
Electron accelerating voltage—350 V to 30 kV (Continuously adjustable)[1]
Electron beam current—1 pA - 22 nA[1]
Electron resolution—0.9 nm at 15 kV; 1.4 nm at 1 kV[1]
Ion source—Liquid Gallium ion emitter[1]
Ion optics—Sidewinder Field emission focused ion beam optics[1]
Ion accelerating voltage—0.5 kV to 30 kV (Continuously adjustable)[1]
Ion beam current—1.5 pA - 20 nA[1]
Ion imaging resolution—5 nm at 30 kV[1]
Ion milling resolution—10 nn on Cr thin film[1]
Scanner resolutions—512x442, 1024x884, 2048x1768, 4096x3536 pixels[1]
Minimum dwell time—25 ns/pixel[1]
Patterning maximum resolution—64k x 64k[1]
Patterning maximum dwell—25 ms/pixel[1]
Detectors—In-lens SE and BSE True Lens Detector (TLD); Everhart-Thornely SE Detector (ETD); 14-Segments solid state STEM II detector; Chamber viewing IR CCD camera[1]
Controller—Microscope controller; LCD Monitor, 19"; Screen resolution 1280x1024; Optical mouse; Chamber door mounted interface for manipulators[1]
Imaging resolution—5 nm at 30 kV[1]
Milling resolution—10 nn on Cr thin film[1]
Resolution—512x442, 1024x884, 2048x1768, 4096x3536 pixels[1]
Maximum resolution—64k x 64k[1]
Minimum dwell—25 ns/pixel[1]
Maximum dwell—25 ms/pixel[1]
Screen resolution—1280x1024[1]
Instrument type—Dual beam focused ion beam (FIB)[1]
Stage—5-axis motorized X-Y-Z-rotate-tilt stage[1]
Stage travel X/Y—150 mm[3]
Stage travel Z—10 mm[1]
Vacuum pump—Edwards XDS10 scroll pump[1]
Sample stage step size—100 nm minimum[1]
Maximum dwell time—25 ms/pixel[1]
Additional included item—Broad beam plasma source ion column (focus 250 µm)[1]
Included documentation—Manuals included[1]
Manipulator—Does not include manipulator[1]
Stage control—5 axes motorized XYZRT 6 in UHR stage with piezo control[3]
Magnification—69x to 2,300,000x[3]
Detector—Through-lens detection for SE and BSE[3]
STEM detector—Retractable[3]
Stage tilt—-10° to +60°[3]
Optional accessories—Omniprobe Autoprobe 200; Ibss Group GV10x plasma cleaner[3]