Power

120V, 50/60Hz[1]

Vacuum

Turbo Pump Controller[1]

How it works

The power supply converts the single-phase AC mains supply into a three-phase, low-voltage, medium-frequency output to power the turbomolecular pump. A single-chip microcomputer generates the variable output frequency and controls the three-phase output voltage based on software and gas load conditions. The controller's internal components include a power transformer, a front panel with an LCD alphanumeric display and keyboard, a rear panel with input/output connectors, and printed circuit boards containing the power supply and three-phase output section, analog and input/output section, microprocessor and digital section, and display and keyboard circuits.[2]

Operation can be conducted via front-panel switches, remote signals through rear-panel connectors, or an RS-232, RS-485, or RS-422 serial link. The controller provides remote start/stop, pump status signals, forepump start/stop, and interlock control for external devices such as pressure switches or water flow switches. An internal EEPROM stores pump operating parameters and programmed input/output information.[2]

What do the numbers mean?

Power & electrical3

Voltage
120V, 50/60Hz[1]
Accurate?
AC Input Voltage
120V, 50/60Hz[1]
Accurate?
Power
120V, 50/60Hz[1]
Accurate?

Vacuum & pumping2

Product type
Turbo Pump Controller[1]
Accurate?
Drive function
drives the Turbo-V 550 turbo pump during the starting phase[2]
Accurate?

Control & software1

Controller type
microprocessor-controlled, solid-state frequency converter[2]
Accurate?

Dimensions & facilities1

Weight
10.7 kg[2]
Accurate?

Configuration & options9

Input Power
600 VA maximum[2]
Accurate?
Output Air Cooling
220 W[2]
Accurate?
Operating Temperature
0 to +40 °C[2]
Accurate?
Model Number
969-9445; 969-9545[3]
Accurate?
Manufacturer
Varian[1]
Accurate?
Model
V 700 HT[1]
Accurate?
Front panel
LCD alphanumeric display and keyboard[2]
Accurate?
Rear panel
input/output connectors[2]
Accurate?
Operating modes
front panel switches; remote signals via rear panel connectors; RS 232/485/422 serial link[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Voltage120V, 50/60Hz[1]
  • AC Input Voltage120V, 50/60Hz[1]
  • Product typeTurbo Pump Controller[1]
  • Power120V, 50/60Hz[1]
  • Drive functiondrives the Turbo-V 550 turbo pump during the starting phase[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What are the model numbers for the Varian Turbo-V 700HT controller?

The controller is available in models 969-9445 and 969-9545.[3]

What is the maximum input power of the controller?

The maximum input power is 600 VA.[2]

What communication interfaces are available on the controller?

The controller supports RS 232, RS 422, and RS 485 serial communication.[2]

What is the operating temperature range of the controller?

The operating temperature range is 0 to +40 °C.[2]

Not publicly documented

The following facts about the V 700 HT Turbo Pump Controller are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the V 700 HT Turbo Pump Controller are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the V 700 HT Turbo Pump Controller are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the V 700 HT Turbo Pump Controller are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the V 700 HT Turbo Pump Controller are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the V 700 HT Turbo Pump Controller is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]ajvs.com — ajvs.comajvs.com
  3. [3]manualslib.com — manualslib.commanualslib.com
Was this page accurate?

Last updated Sep 29, 2026.

Compare with similar tools

View all →