Waferpedia

Thermotron

SE 600 10 10 Environmental

Thermotron SE 600 10 10 Environmental family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

Thermotron SE 600 10 10 Environmental is an environmental test chamber. Thermotron SE 600 10 10 Environmental has a workspace volume of 20.7 ft³. Thermotron SE 600 10 10 Environmental has a temperature range of -70°C to 180°C.[1]

SE 600 10 10 Environmental — Inventory photo
Fig. 01SE 600 10 10 EnvironmentalInventory photo[2]

Power

41 full load amps[1]

Vacuum

30 PSI[3]

Performance

±0.5°C (±0.9°F)[1]

What it is

The Thermotron SE 600 10 10 Environmental is an environmental test chamber. The model is part of Thermotron's SE-Series environmental chamber line.[1][4]

What do the numbers mean?

Power & electrical5

Electrical requirements at 460 / 3 / 60
41 full load amps[1]
Accurate?
Electrical requirements at 400 / 3 / 50
42 full load amps[1]
Accurate?
Electrical requirements at 230 / 3 / 60
81 full load amps[1]
Accurate?
Electrical requirements at 208 / 3 / 60
89 full load amps[1]
Accurate?
Electrical power
230 volt (±5%), 3 phase, 60 cycle; recommended minimum service 90 amps, or 460 volt (±5%), 3 phase, 60 cycle; recommended minimum service 50 amps[3]
Accurate?

Vacuum & pumping2

Minimum pressure
30 PSI[3]2 sources
Accurate?
Maximum pressure
125 PSI[3]2 sources
Accurate?

Performance2

Temperature uniformity
±0.5°C (±0.9°F)[1]
Accurate?
Temperature uniformity
±0.7°C[3]
Accurate?

Control & software2

Temperature control tolerance
0.3°C (0.5°F)[1]2 sources
Accurate?
Humidity control
+/- 2.5% RH[1]
Accurate?

Dimensions & facilities8

Workspace dimensions (WxDxH)
40 x 26.25 x 34 inches (102 x 67 x 86 centimeters)[1]
Accurate?
Approx. shipping weight
2,040 lbs (925 kg)[1]
Accurate?
Move-in dimensions (WxDxH)
49 x 70 x 83 inches (124 x 178 x 211 centimeters)[1]
Accurate?
Workspace dimensions
40" wide x 26.25" deep x 34" high (102 cm wide x 67 cm deep x 86 cm high)[3]
Accurate?
Shipping weight
Approximately 1700 pounds (771 kg)[3]
Accurate?
Cooling water at 85°F inlet temperature
16 GPM[3]
Accurate?
Cooling water at 75°F inlet temperature
9 GPM[3]
Accurate?
Cooling water at 65°F inlet temperature
6 GPM[3]
Accurate?

Configuration & options28

Workspace volume
20.7 ft³ (586 L)[1]
Accurate?
Temperature range
-70°C to 180°C (-94°F to 356°F)[1]
Accurate?
Inlet water at 24°C / 75°F
9 gal/min (34 L/min)[1]
Accurate?
Inlet water at 18°C / 65°F
7.5 gal/min (28 L/min)[1]
Accurate?
Inlet water at 13°C / 55°F
6 gal/min (23 L/min)[1]
Accurate?
Inlet water at 29°C / 85°F
16 gal/min (60 L/min)[1]
Accurate?
Humidity range
10 to 98% RH[1]
Accurate?
Heating performance from -65°C to 71°C
9 minutes[1]
Accurate?
Heating performance from -65°C to 180°C
19 minutes[1]
Accurate?
Heating performance from -40°C to 85°C
8 minutes[1]
Accurate?
Heating rate from -65°C to 71°C
15.1°C/minute[1]
Accurate?
Heating rate from -65°C to 180°C
12.8°C/minute[1]
Accurate?
Heating rate from -40°C to 85°C
15.6°C/minute[1]
Accurate?
Cooling performance from 85°C to -40°C
11 minutes[1]
Accurate?
Cooling performance from 71°C to -65°C
17 minutes[1]
Accurate?
Cooling performance from 180°C to -65°C
28 minutes[1]
Accurate?
Cooling rate from 85°C to -40°C
11.3°C/minute[1]
Accurate?
Cooling rate from 71°C to -65°C
8°C/minute[1]
Accurate?
Cooling rate from 180°C to -65°C
8.7°C/minute[1]
Accurate?
Airflow
1,000 CFM[1]
Accurate?
Workspace volume
20.7 cubic feet (586 liters)[3]
Accurate?
Heated window
15" wide x 19" high (38 cm wide x 48 cm high)[3]
Accurate?
Compressors
Two 10 horsepower scroll compressors in cascade[3]
Accurate?
Chamber heater
16KW[3]
Accurate?
Airflow
Approximately 1000 CFM[3]
Accurate?
Circulator motor
One 1/2 horsepower, 1725 RPM[3]
Accurate?
Construction material
Internal liner: 18 gauge, series 300 stainless steel; exterior: die-formed 16 gauge treated sheet steel[3]
Accurate?
Temperature range
-100°C to +180°C (-95°F to +355°F)[3]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Electrical requirements at 460 / 3 / 6041 full load amps[1]
  • Electrical requirements at 400 / 3 / 5042 full load amps[1]
  • Electrical requirements at 230 / 3 / 6081 full load amps[1]
  • Electrical requirements at 208 / 3 / 6089 full load amps[1]
  • Electrical power230 volt (±5%), 3 phase, 60 cycle; recommended minimum service 90 amps, or 460 volt (±5%), 3 phase, 60 cycle; recommended minimum service 50 amps[3]
  • Minimum pressure30 PSI[3]
  • Maximum pressure125 PSI[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of equipment is the Thermotron SE 600 10 10 Environmental?

The Thermotron SE 600 10 10 Environmental is an environmental test chamber.[4][1]

What workspace volume does the SE 600 10 10 Environmental have?

The SE 600 10 10 Environmental has a workspace volume of 20.7 ft³, or 586 L.[4][1][3]

What temperature range does the SE 600 10 10 Environmental support?

The SE 600 10 10 Environmental supports a temperature range of -70°C to 180°C.[4][1]

What humidity range does the SE 600 10 10 Environmental support?

The SE 600 10 10 Environmental supports a humidity range of 10 to 98% RH.[4]

What are the workspace dimensions of the SE 600 10 10 Environmental?

The SE 600 10 10 Environmental has workspace dimensions of 40 by 26.25 by 34 inches, or 102 by 67 by 86 centimeters.[4][1][3]

Not publicly documented

The following facts about the SE 600 10 10 Environmental are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the SE 600 10 10 Environmental are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the SE 600 10 10 Environmental are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the SE 600 10 10 Environmental are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the SE 600 10 10 Environmental are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the SE 600 10 10 Environmental is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]thermotron.com — thermotron.comthermotron.com
  2. [2]Inventory photo
  3. [3]lre.com — lre.comlre.com
  4. [4]SE 600 10 10 Environmental — Thermotron | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 7, 2026.

Compare with similar tools

View all →