The Tektronix P 6139 A is a 10X passive probe. The Tektronix P 6139 A is designed for use with Tektronix TDS3000 and TDS500 Series digitizing oscilloscopes. The Tektronix P 6139 A has a 1.3 meter cable.[1]

P 6139 A — Inventory photo
Fig. 01P 6139 AInventory photo[2]

What it is

The P6139A is a 10X passive voltage probe designed for use with digitizing oscilloscopes. Passive voltage probes connect an oscilloscope to an electronic circuit while providing a fixed attenuation of the signal.[1][3]

The P6139A is designed for use with Tektronix TDS500, TDS600, TDS700, TDS3000B, and TDS7000B Series oscilloscopes. The probe has a 1.3 meter cable and is fully compatible with Tektronix compact-size (3.5 mm) probe accessories.[1][3]

How it works

Passive voltage probes use a resistive-capacitive divider network to attenuate the input signal by a fixed factor. The P6139A provides 10X attenuation, reducing the signal amplitude by a factor of ten before it reaches the oscilloscope input. Attenuation readout encoding allows the oscilloscope to automatically recognize the probe's attenuation factor.[3]

The P6139A includes a low-frequency compensation adjustment accessible through an opening in the compensation box. The user adjusts the trimmer while observing a 1 kHz calibrated square wave until the displayed waveform shows a perfectly flat top. Proper compensation matches the probe's capacitance to the oscilloscope's input characteristics.[1]

The P6139A uses hybrid/SMT circuitry and modular construction. The probe head and cable assembly are smaller than traditional passive probes, and the probe is compatible with a full line of compact attachment accessories.[3]

Where it fits in the process flow

The P6139A is suited for high- and low-frequency relative measurements. Typical applications include design, service, and manufacturing environments where accurate signal observation is required.[3]

What do the numbers mean?

Power & electrical2

System bandwidth
500 MHz (TDS3054) or TDS500 series; 100 MHz (TDS3012)[1]
Accurate?
Maximum input voltage
400 V RMS CAT I or 400 V DC CAT I; 300 V RMS CAT II or 300 V DC CAT II; 150 V RMS CAT III or 150 V DC CAT III; 590 V peak, <50% DF, <1 sec PW; 930 V peak, <20% DF, <1 sec PW; 1250 V peak, <10% DF, <50 usec PW[1]
Accurate?

Dimensions & facilities1

Net weight including accessories
<110 g (0.24 lb)[1]
Accurate?

Configuration & options12

Type
10X passive probe[1]
Accurate?
Use
Designed for use with Tektronix TDS3000 and TDS500 Series digitizing oscilloscopes[1]
Accurate?
Cable length
1.3 meter[1]
Accurate?
Compatibility
Compatible with the Tektronix family of compact size (3.5 mm) probe accessories[1]
Accurate?
Attenuation
10X ±0.5% at DC[1]
Accurate?
Input resistance
10 MΩ ±0.5%[1]
Accurate?
Input capacitance
8.0 pF (±0.8 pF)[1]
Accurate?
Compensation range
8 pF to 18 pF[1]
Accurate?
Operating temperature range
-15 C to +65 C (+5 F to +149 F)[1]
Accurate?
Nonoperating temperature range
-62 C to +85 C (-80 F to +185 F)[1]
Accurate?
Humidity
Five cycles (120 hr) at 95% to 97% relative humidity[1]
Accurate?
Altitude
< 2000 meters[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • System bandwidth500 MHz (TDS3054) or TDS500 series; 100 MHz (TDS3012)[1]
  • Maximum input voltage400 V RMS CAT I or 400 V DC CAT I; 300 V RMS CAT II or 300 V DC CAT II; 150 V RMS CAT III or 150 V DC CAT III; 590 V peak, <50% DF, <1 sec PW; 930 V peak, <20% DF, <1 sec PW; 1250 V peak, <10% DF, <50 usec PW[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the bandwidth of the Tektronix P6139A probe?

The P6139A has a bandwidth of 500 MHz.[3]

What is the attenuation factor of the P6139A?

The P6139A provides 10X attenuation.[1][3]

With which oscilloscope series is the P6139A compatible?

The P6139A is compatible with Tektronix TDS500, TDS600, TDS700, TDS3000B, and TDS7000B Series oscilloscopes.[3]

What is the input capacitance of the P6139A?

The P6139A has an input capacitance of 8 pF.[3]

What is the maximum input voltage rating of the P6139A?

The maximum input voltage is 300 VRMS CAT II (with a note that DC + peak AC must not exceed 500 V).[3]

Not publicly documented

The following facts about the P 6139 A are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the P 6139 A are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the P 6139 A are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the P 6139 A are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the P 6139 A are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the P 6139 A is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]download.tek.com — download.tek.comdownload.tek.com
  2. [2]Inventory photo
  3. [3]https://www.testequipmenthq.com/datasheets/TEKTRONIX-P6139A-Datasheet.pdf — testequipmenthq.comtestequipmenthq.com
Was this page accurate?

Last updated Oct 7, 2026.

Compare with similar tools

View all →