Waferpedia

Pfeiffer

DCU 400 Digital Control Unit Turbomolecular Pump Controller

Pfeiffer DCU family
Research Quality: 50% complete

The Pfeiffer DCU 400 is a digital control unit for turbomolecular pumps with an integrated mains power unit. The DCU 400 provides a 48 V DC output at 8.4 A (approximately 400 W). The DCU 400 features a front LCD and keypad, and uses convection cooling.[1][2][3]

DCU 400 Digital Control Unit Turbomolecular Pump Controller — Inventory photo
Fig. 01DCU 400 Digital Control Unit Turbomolecular Pump ControllerInventory photo[1]

Power

100 – 240 V AC, 5.2 – 1.7 A, 50/60 Hz[1]

Vacuum

86 kPa - 106 kPa[2]

What it is

The Pfeiffer DCU 400 is a digital control unit for a turbomolecular pump controller.[1][4]

The DCU 400 uses 100–240 V AC input power and provides 48 V DC output power.[1][4]

How it works

The DCU 400 has a front LCD and keypad for local operation. The DCU 400 also uses convection cooling.[1][4]

Applications

The DCU 400 is used with turbomolecular pumping hardware in vacuum systems. The unit is suited to pump control and monitoring in setups that require electronic drive control and pressure-gauge connection.[2]

What do the numbers mean?

Power & electrical5

Input Power
100 – 240 V AC, 5.2 – 1.7 A, 50/60 Hz[1]
Accurate?
Output Power
48 V DC @ 8.3 A (≈ 400 W)[1]
Accurate?
Output Voltage
48 V DC (± 2 %)[3]
Accurate?
Input Voltage (mains)
115-230 V AC (-20/+15%), 50/60 Hz[2]
Accurate?
Recommended Electronic Drive Units
TC 400 (48 V DC), TC 120 (48 V DC), TM 700[3]
Accurate?

Vacuum & pumping1

Air Pressure
86 kPa - 106 kPa[2]
Accurate?

Dimensions & facilities1

Weight
2.3 kg[3]
Accurate?

Configuration & options9

Front LCD + keypad[1]
Accurate?
Cooling
Convection[1]
Accurate?
Output Current
8.4 A[3]
Accurate?
Max. Power Consumption
450 VA[3]
Accurate?
Front Panel
Front LCD + keypad[1]
Accurate?
Protection Type
IP20[2]
Accurate?
Ambient Temperature
5 - 50°C[2]
Accurate?
Relative Humidity
5 - 85%, non-condensing[2]
Accurate?
Part Number
PM C01 823 / PMC01823[3]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Input Power100 – 240 V AC, 5.2 – 1.7 A, 50/60 Hz[1]
  • Output Power48 V DC @ 8.3 A (≈ 400 W)[1]
  • Output Voltage48 V DC (± 2 %)[3]
  • Input Voltage (mains)115-230 V AC (-20/+15%), 50/60 Hz[2]
  • Air Pressure86 kPa - 106 kPa[2]
  • Recommended Electronic Drive UnitsTC 400 (48 V DC), TC 120 (48 V DC), TM 700[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the DCU 400 Digital Control Unit Turbomolecular Pump Controller are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the DCU 400 Digital Control Unit Turbomolecular Pump Controller are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the DCU 400 Digital Control Unit Turbomolecular Pump Controller are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the DCU 400 Digital Control Unit Turbomolecular Pump Controller are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the DCU 400 Digital Control Unit Turbomolecular Pump Controller are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the DCU 400 Digital Control Unit Turbomolecular Pump Controller is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]idealvac.com — idealvac.comidealvac.com
  3. [3]ptbsales.com — ptbsales.comptbsales.com
  4. [4]DCU 400 Digital Control Unit Turbomolecular Pump Controller — Pfeiffer | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 11, 2026.

Compare with similar tools

View all →