Waferpedia

Comparison ledger

Epsilon 2000versus150LX

ASM Epsilon 2000, Kurt Lesker 150LX, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
150LXKurt Lesker
OEMASMKurt Lesker
CategoryDepositionDeposition
Wafer size150mm150mm
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyASM EpsilonKurt Lesker 150LX
Specifications
Supply Voltage/ Freq480/ 50[1]—
System HandRight Hand[1]—
Monitor TypeFlat Panel[1]—
Wafer Size150mm[1]—
Maint ConsoleMini Maint[1]—
CPU68040[1]—
Software Version7.65[1]—
CommsHSMS[1]—
RP/ ATMRP[1]—
Vacuum Load LocksNo[1]—
WHC Gate ValveSwing[1]—
WHC Robot ArmWide[1]—
Reactor IsolationHVA[1]—
ATM ValveVAT[1]—
Pressure ControllerMKS 152 Analogue[1]—
PCV TypeMKS 253B[1]—
Choke ValveYes[1]—
RP OrientationBottom Feed[1]—
Gas Panel OrientationTop Feed[1]—
Main H2/N2100slm[1]—
Process typeCVD (Chemical Vapor Deposition)[1]Plasma-enhanced atomic layer deposition (PE-ALD)[4]
Wafer sizes supported150 mm and 200 mm wafers[3]—
Tool typesingle-wafer epitaxy tool[3]—
Supply voltage/frequency480/50[1]—
OEM—Kurt Lesker[4]
Model—ALD-150LX[4]
Type—Plasma-enhanced atomic layer deposition (PE-ALD) system[4]
Location—Cleanroom[4]
Operating mode—Load-locked system[4]
In situ metrology—Film Sense FS-1 Multi-Wavelength ellipsometer[4]
Wafer size—Up to full 150 mm (6") wafers[4]
Process—Plasma-enhanced atomic layer deposition (PE-ALD)[4]
Substrate size—Up to 150mm[5]
Substrate heating—Up to 600°C[5]
Load lock—Load-locked system[4]
ALD process modes—Plasma Enhanced, Thermal only, Dynamic and Static Exposure for HAR, Variable Residence Mode (VRM)[5]
Ellipsometry—Standard on chamber[5]
Precursor inlets to chamber—Four (4), standard on chamber, independently heated[5]
Precursor sources—Up to twelve (12)[6]
Precursor types—Up to fourteen (14)[5]
Plasma source—1 kW RF remote ICP[7]
Substrate temperature—Up to 600°C[5]
Process modes—Plasma enhanced, thermal only, dynamic and static exposure for HAR, variable residence mode (VRM)[5]
Ellipsometry ports—Standard on chamber[5]
Precursor inlets—Four standard on chamber, independently heated[5]
Precursor capacity—Up to fourteen vapor draw flow through, bubbler, ozone pulsed gas plasma process gases[5]
Substrate handling—Load locked single wafer transfer[7]
Process gases—Argon, oxygen, nitrogen, hydrogen, ammonia, ozone[7]

Plan your fab

Building a Deposition process? Get a complete equipment list.

Open the fab equipment planner →
Sources (7)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]inventory listing
  3. [3]asm.comasm.com
  4. [4]smif.pratt.duke.edusmif.pratt.duke.edu
  5. [5]lesker.comlesker.com
  6. [6]mrl.illinois.edumrl.illinois.edu
  7. [7]confluence.nanofab.ualberta.caconfluence.nanofab.ualberta.ca