Waferpedia

Comparison ledger

-407B-1-S-CES293 RobotversusLambda 35

ABM -407B-1-S-CES293 Robot, Perkin Elmer Lambda 35, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
Lambda 35Perkin Elmer
OEMABMPerkin Elmer
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-1-S-CES293 RobotPerkin Elmer Lambda 35
Cited variants—
Specifications
ModelABM-407B-1-S-CES293[2]—
DescriptionROBOT[2]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[2]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[2]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[2]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[2]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[2]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[2]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[2]—
Instrument type—Scanning double-beam spectrometer for the UV/Vis range; operation by PC[1]
Wavelength range—190 nm to 1100 nm[1]
Spectral bandwidth—0.5 nm, 1 nm, 2 nm, 4 nm (selectable fixed slit widths)[1]
Detector—Photodiodes, one for the sample beam and one for the reference beam[1]
Radiation sources—Prealigned deuterium and halogen lamps[1]
Photometric range—Transmission 0% to 100%; absorbance -6.000 to 6.000; concentration units 1 to 9999[1]
Photometric accuracy—Absorbance ±0.003 at Absorbance = 1 at 440 nm, 546.1 nm and 635 nm; absorbance ±0.015 at Absorbance = 1 at 257 nm and 350 nm[1]
Stray radiation—Transmission <0.02% at 220 nm, 340 nm and 370 nm; absorbance >2 at 200 nm with potassium chloride solution against distilled water[1]
Baseline stability—Absorbance <0.0003 per hour at 500 nm after warmup[1]
Beam center height—15 mm above cell holder bottom[1]
Optical pathlength in sample compartment—121 mm[1]
Interface—One RS 232 C interface (serial) for connecting a PC[1]
Use cases—Measurements on liquids, solids, pastes and powder samples[3]
Modes of operation—Scanning, wavelength program, time-drive, rate, quant, scanning quant[4]
Type—Scanning double-beam spectrometer for the UV/Vis range; operation by PC[1]
Dimensions—Width: 650 nm; Height: 260 nm; Depth: 560 nm[1]
Mass—26 kg approx.[1]
Power requirements—100 V to 240 V AC, 50/60 Hz; 250 VA[1]
Ambient operating temperature—15 ºC to 35 ºC[1]
Humidity range—20% to 80% relative humidity without condensation[1]
Wavelength accuracy—±0.1 nm[1]
Wavelength reproducibility—±0.1 nm[1]
Lamp change—Automatically at 326 nm (software selectable over the whole wavelength range)[1]
Scan speeds—7.5, 15, 30, 60, 120, 240, 480, 960, 1920 and 2880 nm/min[1]
Baseline linearity—2 nm slit: Absorbance ±0.0005 (corrected: 200 nm to 1100 nm, scan speed 240 nm/min, smooth 2)[1]
Baseline noise—2 nm slit: Absorbance < 0.00006 RMS; Absorbance < 0.0002 peak-to-peak 3 min at Absorbance = 0, wavelength 500 nm and response 2 s[1]
Data output—One RS 232 C interface (serial), for connecting a PC[1]
Optical system—All-reflecting optical system with silica-coated optical components and a holographic concave grating with 1053 lines/mm in the center[1]
Beam cross-section—0.5 nm slit ca. 0.25 mm x 7 mm; 1 nm slit ca. 0.5 mm x 7.5 mm; 2 nm slit ca. 1 mm x 7.5 mm; 4 nm slit ca. 2 mm x 7.5 mm[1]
Grating—Holographic concave grating with 1053 lines/mm in the center[1]
Baseline stability (drift)—Absorbance < 0.0003 per hour at 500 nm after warmup[1]