1050 UV-VISversusAPI 3000

Perkin Elmer 1050 UV-VIS, SCIEX API 3000, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
1050 UV-VISPerkin Elmer
OEMPerkin ElmerSCIEX
CategoryPrecision OpticsPrecision Optics
Wafer size——
Process node——
Introduced——
Production run—1998–
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyPerkin Elmer 1050 UV-VISSCIEX API 3000
Specifications
Asset ID82948[1]—
Last Confirm DateAugust 23, 2024[1]—
ManufacturerPerkin Elmer[1]—
Model1050[1]—
Instrument typeSpectrometer[1]triple quadrupole mass spectrometer[2]
UseAnalyzing ultraviolet and visible light absorption spectra[1]—
manufacturer—SCIEX[2]
model mention context—API 3000[2]
product family context—turbo-molecular-pumped single and triple quadrupole mass spectrometer products[2]
Mass Analyzer—Triple quadrupole (Q1q2Q3)[3]
Ionization Source—Atmospheric Pressure Ionization (API) with TurboIonSpray and Heated Nebulizer (APCI) options[4]
Collision Cell—LINAC collision cell[3]
Interface Technology—Curtain Gas interface[3]
Operating System / Software—Windows NT platform-based Analyst software[3]
Electrical Requirement (Main Power)—207–242 VAC, 50/60 Hz, 15 A per circuit, two circuits required[4]
Power Consumption (Mass Spectrometer + Roughing Pump)—220 VAC at 13–15 A (nominal)[4]
Curtain Gas Requirement—UHP N2 (99.999%) at 60 psig, flow up to 3.5 L/min[4]
Gas 1 Requirement (Nebulizer/Auxiliary)—Zero air or UHP N2 (99.999%) at 90 psig, flow up to 4.0 L/min[4]
Gas 2 Requirement (Heater/Nebulizer)—Zero air or UHP N2 (99.999%) at 90 psig, flow up to 8.0 L/min[4]
Source Exhaust Gas Requirement—Clean, dry, oil-free air at 50 psig, flow up to 8.0 L/min[4]
Operating Temperature Range—15–30 °C (59–86 °F)[4]
Operating Relative Humidity—20–80% non-condensing[4]
Pumping technology—turbo-molecular-pumped[2]
Era of introduction—1998[2]
Mass spectrometer type—Triple quadrupole[5]
Ionization method—Atmospheric Pressure Ionization (API)[4]
Collision cell technology—LINAC collision cell[5]
Software platform—Analyst software on Windows NT[5]
Dimensions (depth x length x height)—50 cm x 130 cm x 52 cm[4]
Weight—147 kg (approx.)[4]
Electrical requirements—207-242 VAC, 15 A, single phase[4]
Gas 1 (nebulizer) supply—Zero air or UHP N2 at 90 psig, up to 4 L/min[4]
Curtain/CAD gas supply—UHP N2 at 60 psig, up to 3.5 L/min[4]

Plan your fab

Building a Precision Optics process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]waferpedia.comwaferpedia.com
  2. [2]en.wikipedia.orgen.wikipedia.org
  3. [3]triadsci.comtriadsci.com
  4. [4]cdn.labwrench.comcdn.labwrench.com
  5. [5]shop.labexchange.comshop.labexchange.com