Comparison ledger
Agilent N 9020 A Signal Analyzer, Applied Materials 0010-03254 E Chuck, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | N 9020 A Signal AnalyzerAgilent | 0010-03254 E ChuckApplied Materials |
|---|---|---|
| OEM | Agilent | Applied Materials |
| Category | — | — |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | Agilent N 9020 A Signal Analyzer | — |
| Cited variants | — | |
| Specifications | ||
| Frequency range options | Option 503: 20 Hz to 3.6 GHz; Option 508: 20 Hz to 8.4 GHz; Option 513: 20 Hz to 13.6 GHz; Option 526: 20 Hz to 26.5 GHz[1] | — |
| Frequency range (data sheet) | 10 Hz to 3.6, 8.4, 13.6, or 26.5 GHz[2] | — |
| Resolution bandwidth (RBW) range | 1 Hz to 3 MHz (standard), up to 70 MHz with Option B85 or B1A and Option RBE, up to 133 MHz with Option B1X and Option RBE[2] | — |
| Analysis bandwidth options | Standard: 10 MHz; Option B25: 25 MHz; Option B40: 40 MHz; Option B85: 85 MHz; Option B1A: 125 MHz; Option B1X: 160 MHz[2] | — |
| Total absolute amplitude accuracy at 50 MHz | ±0.33 dB (10 dB attenuation, 20 to 30 °C, 1 Hz ≤ RBW ≤ 1 MHz)[2] | — |
| Displayed average noise level (DANL) at 1 GHz | –144 dBm (specification, 20 to 30 °C, 1 Hz RBW, preamp off)[2] | — |
| Model | N 9020 A[3] | — |
| Make | Agilent[3] | — |
| Instrument type | Signal Analyzer[3] | — |
| Series | MXA X-Series signal analyzer[2] | — |
| Frequency range, option 503 | 10 Hz to 3.6 GHz[2] | — |
| Frequency range, option 508 | 10 Hz to 8.4 GHz[2] | — |
| Frequency range, option 513 | 10 Hz to 13.6 GHz[2] | — |
| Frequency range, option 526 | 10 Hz to 26.5 GHz[2] | — |
| Standard analysis bandwidth | 10 MHz[1] | — |
| Optional analysis bandwidth | 25 MHz[1] | — |
| Resolution bandwidth range | 1 Hz to 8 MHz[1] | — |
| Video bandwidth range | Same as resolution bandwidth range plus wide-open VBW labeled 50 MHz[1] | — |
| Input attenuation range | 0 to 70 dB in 2 dB steps[1] | — |
| Maximum safe input level, average total power | +30 dBm (1 W)[1] | — |
| Maximum safe input level, peak pulse power | <10 μs pulse width, <1% duty cycle, input attenuation ≥ 30 dB: +50 dBm (100 W)[1] | — |
| Display resolution | 1024 x 768, XGA[2] | — |
| Operating temperature range | 0 to 55 °C[2] | — |
| Storage temperature range | -40 to 70 °C[2] | — |
| Power consumption, on | 465 W maximum[2] | — |
| Weight, net | 18 kg (40 lbs), nominal[2] | — |
| Dimensions, height | 177 mm (7.0 in)[2] | — |
| Dimensions, width | 426 mm (16.8 in)[2] | — |
| Dimensions, length | 368 mm (14.5 in)[2] | — |
| Warranty | 3-year warranty[2] | — |
| Recommended calibration cycle | Two years[2] | — |
| Product line | MXA X-Series Signal Analyzer[2] | — |
| Calibration cycle | Two years[2] | — |
| Frequency range | 10 Hz to 3.6, 8.4, 13.6, or 26.5 GHz[2] | — |
| Maximum frequency options | 3.6 GHz, 8.4 GHz, 13.6 GHz, or 26.5 GHz[2] | — |
| Instrument line | MXA signal analyzer[2] | — |
| Frequency range, DC-coupled | 10 Hz to 3.6 GHz / 8.4 GHz / 13.6 GHz / 26.5 GHz depending on option[2] | — |
| Frequency range, AC-coupled | 10 MHz to 3.6 GHz / 8.4 GHz / 13.6 GHz / 26.5 GHz depending on option[2] | — |
| Trace points | 1 to 40001[2] | — |
| Sweep time range, span >= 10 Hz | 1 ms to 4000 s[2] | — |