Waferpedia

Comparison ledger

-407B-2-S-CE-S293 RobotversusN 5230 A Network Analyzer

ABM -407B-2-S-CE-S293 Robot, Agilent N 5230 A Network Analyzer, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMABMAgilent
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-2-S-CE-S293 RobotAgilent N 5230
Cited variants—
  • N5230A Option 025/125[1]
  • N5230A Option 225[1]
  • N5230A Option 425/525[1]
  • N5230A Option 240[2]
  • N5230A Option 245[2]
Specifications
ModelABM-407B-2-S-CE-S293[3]—
DescriptionROBOT[3]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[3]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[3]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[3]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[3]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[3]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[3]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[3]—
High dynamic range—127 dB at 20 GHz at test port[4]
Low trace noise—0.002 dB rms at 1 kHz bandwidth[4]
Fast measurement speed—4.5 to 26 ìsec/point[4]
High stability—0.05 dB/degrees Celsius[4]
Configuration—State-of-the-art calibration capabilities and wide-range of ECal modules[4]
Frequency range (2-port options)—300 kHz to 6 GHz, 300 kHz to 13.5 GHz, 10 MHz to 20 GHz, 10 MHz to 40 GHz, 10 MHz to 50 GHz[1]
Frequency range (4-port options 240/245)—300 kHz to 20 GHz[2]
Dynamic range at 20 GHz at test port—127 d B[4]
System dynamic range (typical, 2–6 GHz, standard test set)—121 d B specification, 110 d B typical[1]
Trace noise (1 kHz bandwidth)—0.002 d B rms[4]
Measurement speed—4.5 to 26 μsec/point[4]
Stability—0.05 d B/°C[4]
Measurement channels—32[4]
Points per channel—16,001[4]
Connectivity—Windows XP, 6 USB connectors, LAN, GPIB[4]
Number of ports (base)—2-port[1]
4-port options—Options 240 and 245[2]
Frequency resolution—1 Hz[2]
CW accuracy—±1 ppm[2]
Frequency stability—±0.05 ppm from -10° to 70° C, ±0.1 ppm/yr maximum[2]
Sources (4)Every fact above is drawn from these public sources
  1. [1]trsrentelco.comtrsrentelco.com
  2. [2]testequipment.centertestequipment.center
  3. [3]dealer listingsemistarcorp.com
  4. [4]inventory listing